3.5 RS-485 Operation
It is possible to network up to 16 x PPM3 programmers on an RS-485 network and control them from
a single ‘Supervisor PC’ running a single session of the Equinox EQTools or ISP-PRO software. This
scenario requires that each PPM3 programmer is set to ‘RS-485’ operation and that a unique ‘Node
Address’ is set for each programmer. An RS-232 to RS-485 converter is also required to convert the
RS-232 signal from the PC COM port to an optically isolated RS-485 signal suitable for interfacing
with the PPM3’s on the network.
The typical setup is shown in the figure below.
Fig. 3.5 Setup for RS-485 Communications (Multi channel)
For RS-485 operation:
?
?
?
?
?
?
?
?
?
?
?
?
Place the PPM3 programmers side-by-side on a flat surface with the rear panels all facing in
the same direction as detailed in fig. 3.5
For each PPM3 programmer, set the RS-232 / RS-485 DIP Switch (5) to the RS-485 position
For each PPM3 programmer set the required Node Address in the range 0 – 15.
(Each programmer must have unique address. It is customary to start have the first
programmer set to address 0, the next programmer in the chain at address 1 and so on. See
section 3.3 for further details.)
Plug the 9-way RS-232 cable into the port on the RS-232 to RS-485 converter and connect
the other end of the cable to a spare PC COM port.
Plug an RS-485 network cable from one of the RS-485 outputs on the RS-485 converter to the
‘RS-485 Input’ connector (left-hand connector) on the rear panel of the first PPM3 Module.
Plug another RS-485 network cable from the ‘RS-485 Output’ connector (right-hand
connector) on the rear panel of the first PPM3 to the next PPM3 in the chain.
A return RS-485 cable from the last PPM3 in the chain to the RS-485 converter is NOT
required.
Power up the PC.
Plug in and switch on the power supply adaptor supplied with the RS-232/RS-485 convertor
into a spare mains socket.
Power up all PPM3 Programmers.
Launch the ISP-PRO software on the PC and set up the required number of PPM’s within the
software.
Test that all PPM3’s are communicating with the PC at their correct ‘Node Address’. (The
Node Address may be changed while the programmer is powered up).
PPM3 MKII Programmer - User Guide - V1.04 - 10 th May 2008
53
相关PDF资料
PPM3A1-UPG5M UPGRADE PPM3 RAC DEVELOPMENT
PQ-MDS-PCIEXP PCI EXPANDER ADAPTOR
PQF-44 PLUG QFP 44PIN (SOLDER DOWN)
PRG18BB471MS1RB THERMISTOR
PS1600 POWER SUPPLY HOTSWAP 90-245V
PS5100EV KIT EVALUATION PS5100 W/PS051
PS5162EV KIT EVALUATION PS5162 W/PS051
PS5163 MODULE BATTERY MGR W/LED DISPLAY
相关代理商/技术参数
PPM3-MK2(UN) 制造商:Equinox Technologies 功能描述:PROGRAMMER ISP
PPM-4 功能描述:电线鉴定 Pre-Printed Marker Cards, Hi-Temp, .25" RoHS:否 制造商:TE Connectivity / Q-Cees 产品:Labels and Signs 类型: 材料:Vinyl 颜色:Blue 宽度:0.625 in 长度:1 in
PPM-46 制造商:Panduit Corp 功能描述:
PPM-47 制造商:Panduit Corp 功能描述:
PPM-49 制造商:Panduit Corp 功能描述:
PPM4-MK1(UN) 制造商:Equinox Technologies 功能描述:ISP PRODUCTION PROGRAMMER
PPM4MK1-UPG15 功能描述:UPGRADE PPM4 ATMEL AT91SAM7 RoHS:是 类别:编程器,开发系统 >> 软件 系列:- 标准包装:1 系列:ISE® 设计套件 类型:订阅 适用于相关产品:Xilinx FPGAs 其它名称:Q4986209T1081384
PPM4MK1-UPG7 功能描述:UPGRADE PPM4 AVR JTAG RoHS:是 类别:编程器,开发系统 >> 软件 系列:- 标准包装:1 系列:ISE® 设计套件 类型:订阅 适用于相关产品:Xilinx FPGAs 其它名称:Q4986209T1081384